Femto-laser keratoplasty using a ring-shaped corneal implant 359º in the treatment of keratoconus
Yu.Yu. KALINNIKOV, I.E. IOSHIN, A.R. GRIGORYAN, A.I. BEZZABOTNOV
Clinical Hospital of the Executive Office of the President of the Russian Federation, 45 Losinoostrovskaya Str., Moscow, Russian Federation, 107150
Kalinnikov Yu.Yu. ― D. Med. Sc., ophthalmologist of the Ophthalmology Department, e-mail: ykalinnikov@gmail.com
Ioshin I.E. ― D. Med. Sc., Professor, Head of the Ophthalmology Department, e-mail: igor.ioshin@gmail.com
Grigoryan A.R. ― ophthalmologist of the Ophthalmology Department, e-mail: gralru24@mail.ru
Bezzabotnov A.I. ― ophthalmologist of the Ophthalmology Department, e-mail: magnawer@ya.ru
The study evaluated the clinical and functional results of the use of open corneal ring 359° in the treatment of keratoconus using a femtosecond laser for the formation of an intrastromal tunnel. 57 eyes of 51 patients were operated with keratoconus of 2-3 stage. Follow-up comprised 24 months. After the open corneal ring implantation, the cylindrical component of refraction decreased by 70.5%, the spherical component ― by 83%. The functional results showed significant improvement of visual acuity without correction by 33% and with correction ― by 40%.
Key words: keratoconus, intralamellar keratoplasty, implantation of 359° open corneal ring.
REFERENCES
- Sevostyanov E.N., Gorscova E.N. Keratoconus plus, 2006, pp. 6-61. (in Russ.)
- Rabinovitz Yu.S. Definition, etiology and diagnosis of keratoconus. Ophthalmol, 2004, no. 21, pp. 241-260.
- Dronov M.M. Keratoconus: diagnosis and treatment, 2008, 120 p. (in Russ.)
- Fleming J.F., Reynolds A.E., Kilmer L. The intrastromal corneal ring: two cases in rabbits. Refract Surg, 1987, no. 3, pp. 227–32.
- Fleming J.F., Wan W.L., Schanzlin D.J. The theory of corneal curvature change with the intrastromal corneal ring. CLAO J, 1989, no. 15, pp. 146-150.
- Burris T.E., Baker P.C., Ayer C.T., Loomas B.E., Mathis M.L., Silvestrini T.A. Flattening of central corneal curvature with intrastromal corneal rings of increasing thickness: an eye- bank eye study. Cataract Refract Surg, 1993, no. 19, pp. 182-187.
- Burris T.E. Intrastromal corneal ring technology: results and indications. Opin. Ophthalmol, 1998, no. 9, pp. 9-14.
- Nose W., Neves R.A., Schanzlin D.J., Belfort R. Intrastromal corneal ring – one-year results of first implants in humans: a preliminary nonfunctional eye study. Corneal Surg, 1993, no. 9 (6), pp. 452-458.
- Ferrara de A., Cunha P. Tecnica cirurgica para correcao de miopia; Anel corneano intra-estromal. Bras. Oftalmol, 1995, no. 54, pp. 577-588.
- Colin J., Cochener B., Savary G., Malet F., Holmes-Higgin D. INTACS inserts for treating keratoconus. Ophthalmalogy, 2001, no. 108(8), pp. 1409-1144.
- Kalinnikov Yu.Yu., Moroz Z.I., Kovshun E.V., Gurbanov R.C. Clinical functional results of implantation of new model of intrastromal corneal segments in patients with keratoconus. Fedorovskiye chteniya-2008, Sbornik nauchnih statey, pp. 321–322. (in Russ.)
- Daxer A. Adjustable intracorneal ring in a lamellar pocket for keratoconus. Refract. Surg., 2010, no. 26, pp. 217-221.
- Daxer A., Mahmoud H., Venkateswaran R.S. Intracorneal continuous ring implantation for keratoconus: one-year follow-up. Cataract Refract Surg., 2010, no. 36, pp. 1296 –302.
- Alio J.L., Pinero D.P., Daxer A. Clinical Outcomes After Complete Ring Implantation in Corneal Ectasia using the Femtosecond Technology. Ophthalmology, 2011, no. 118, pp. 1282-1290.
- Mahmoud H., Venkateswaran R.S., Daxer A. Implantation of a complete corneal ring in an intrastromal pocket for keratoconus. Refract. Surg, 2011, no. 27, pp. 63-68.
- Maslova N.A., Suslikov S.V. Forming of intrastromal corneal tunnels for implantation corneal segments in patients with keratoconus using IntraLase femtosecond laser. Buleten SO RAMN, 2009, no. 4 (138), pp. 75-79. (in Russ.)
- Neroev V.V., Oganesyan O.G., Penkina A.V., Khandzhyan A.N. The results of the implantation of intrastromal corneal segments using femtosecond surgical laser FEMTO LDV implants in patients with keratoconus of II-III stage. Proceedings of III Russian national ophthalmic Forum – Мoscow, 2010, Vol. 1, pp. 137-141. (in Russ.)
- Shabayek M.H., Alio J.L. Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction. Ophthalmology, 2007, no. 114, pp. 1643-1652.
- Kalinnikov Yu.Yu., Ioshin I.E., Leontieva G.D., Novikov S.V., Selifanov Y.V., Grigoryan A.R. The first experience of using annular intrastromal corneal implants in patients with keratoconus. Sovremennyye tekhnologii kataraktalnoy i refraktsionnoy khirurgii – 2013, Sbornik nauchnikh statey, pp. 232-237. (in Russ.)
- Kalinnikov Yu.Yu., Ioshin I.E., Grigoryan A.R. Intrastromal corneal ring implantation to correct high astigmatism after deep anterior lamellar keratoplasty. Kataraktalnaya i refraktsionnaya khirurgiya, 2015, vol. 15, no. 4, pp. 30-34. (in Russ.)