Choice of femto-assisted trepanation parameters based on intraoperative thickness control of the donor cornea
I.A. ISKAKOV1, I.B. DRUZHININ1, L.V. SHCHERBAKOVA2
1Novosibirsk branch of the S. Fyodorov Eye Microsurgery Federal State Institution, 10 Kolkhidskaya Str., Novosibirsk, Russian Federation, 630071
2Scientific-Research Institute for Therapy and Preventive Medicine, 175/1 Bogatkov Str., Novosibirsk, Russian Federation, 630089
Iskakov I.A. ― D. Med. Sc., Head of the Operating Department, tel. (383) 340-44-73, e-mail: i.iskakov@mntk.nsk.ru
Druzhinin I.B. ― Cand. Med. Sc., surgeon-ophthalmologist, tel. (383) 341-57-79, e-mail: druzhinins@rambler.ru
Shcherbakova L.V. ― Senior Researcher of the Laboratory of Clinical-Population and Preventive Studies of Therapeutic and Endocrine Diseases, e-mail: 9584792@mail.ru
The article presents the results of intra-operative research of the thickness of donor cornea with the portable optical coherent tomograph iVue-100. During hypothermic preservation in storage media Eusol-C, the cornea fiber hydration increases. The average minimum thickness of donor cornea was 642.9±40.8 µ. basing on multifactor regression analysis, we have found the statistically reliable dependence of the thickness of donor cornea kept under hypothermic conditions on the time period since the donor’ death. The optimal femtolaser parameters (VICTUS femtolaser device) for penetrating trepanation of donor cornea were identified, which allowed to carry out complete high-quality trepanation and avoid additional use of cutting tools. The reduction of the storing period of donor cornea allows to decrease the energy impact on the fiber of donor cornea.
Key words: femtokeratoplasty, hypothermic storage, optical coherent tomography.
REFERENCES
- Mian S.I., Shtein R.M. Femtosecond laser-assisted corneal surgery. Curr Opin Ophthalmol, 2007, Vol. 18, no. 4, pp. 295-299.
- Kostenev S.V., Chernykh V.V. Femtosecond laser surgery, 2012. 142 p.
- Mannis M.J., Holland E.J., Gal R.L., et al. The Effect of Donor Age on Penetrating Keratoplasty for Endothelial Disease: Graft Survival after 10 Years in the Cornea Donor Study. Ophthalmology, 2013, Vol. 120, no. 12. 10 p.
- Borzenok S.А. Medico-technological and methodological foundations of the effective activity of the eye tissue banks of Russia in providing operations for penetrated transplantation of the cornea. Avtoref. Thesis. … doctor of of honey, 2008. 50 p.
- Zabolotnykh A.G., Sakhnov S.N., Kiselev A.V. Organization of the regional tissue donation service «Eye Bank» — organizational and methodological support of high-technology keratotransplantology in the Krasnodar Region. Bulletin of the TSU, 2014. no. 19, pp. 1120-1123.
- Mergler S., Pleyer U. The human corneal endothelium: new insights into electrophysiology and ion channels. Prog Retin Eye Res, 2007, Vol. 26, no. 4, pp. 359-378.
- Malyugin B.E., Pashtaev N.P., Pashtaev A.N. Femtolaser anterior lamellar keratoplasty: a pilot clinical study. Ophthalmosurgery, 2014, no. 2, pp. 24-28.
- Kostenev S.V., Litasova Yu.A., Chernykh V.V. Investigation of changes in the shape and thickness of the cornea after Laser in situ keratomileusis (LASIK). Ophthalmosurgery, 2010, no. 2, pp. 4-7.
- Kopaeva V.G. Modern Aspects of Penetrated Subtotal Keratoplasty. Abstract. Thesis. … doctor of honey, 1982. 32 p.
- Iskakov I.A., Druzhinin I.B. Femtoassistance for various types of keratoplasty. Modern technology in ophthalmology, 2015, Vol. 8, no. 4, pp. 138-140.
- Farid M., Steinert R.F. Femtosecond laser-assisted corneal surgery. Curr Opin Ophthalmol, 2010, Vol. 21, no. 4, pp. 288-292.
- Nuzzo V. Mechanisms of femtosecond laser-cornea interaction in keratoplasty // https://pastel.archives-ouvertes.fr/pastel-00005010
- Holzer M.P., Rabsilber T.M., Auffarth G.U. Penetrating keratoplasty using femtosecond laser. Am J Ophthalmol, 2007, Vol. 143, no. 3, pp. 524-526.
- Nuzzo V., Aptel F., Savoldelli M. et al. Histologic and ultrastructural characterization of corneal femtosecond laser trephination. Cornea, 2009, Vol 28, no. 8, pp. 908-913.
- Serrao S., Buratto L., Lombardo G. et al. Optimal parameters to improve the interface quality of the flap bed in femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg, 2012, Vol. 38, no. 8, pp. 1453-1459.
- Fedorov S.N., Moroz Z.I., Borzenok S.A. et al. Medium for the preservation of the cornea of the eye. Patent RF., N 2069951, 10.12.1996.
- Pels E., Beele H., Claerhout I. Eye bank issues: II. Preservation techniques: warm versus cold storage. Int Ophthalmol, 2008, Vol. 28, no. 3, pp. 155–163.
- Cornea Donor Study Investigator Group. The Effect of Donor Age on Corneal Transplantation Outcome: Results of the Cornea Donor Study. Ophthalmology, 2008, Vol. 115, no. 4, pp. 620-626.
- Meltendorf C., Schroeter J., Reinhold B. et al. Corneal trephination with the femtosecond laser. Cornea, 2006, no. 25, pp. 1090–1092.