Biocompatible allogenic bone implant in ophthalmic surgery
L.M. TSUROVA1,2, E.S. MILYUDIN1,2, L.T. VOLOVA2
1Samara Regional Clinical Ophthalmologic Hospital named after T.I. Eroshevsky, 158 Novo-Sadovaya Str., Samara, Russian Federation, 443068
2Samara State Medical University, 89 Chapaevskaya Str., Samara, Russian Federation, 443099
Tsurova L.M. ― ophthalmosurgeon of the Traumatology Department, consultant physician of the Laboratory of Eye Prostheses, researcher, tel.: (846) 926-21-46, e-mail: leyla_tsurova@mail.ru
Milyudin E.S. ― D. Sc. (medicine), ophthalmologist, Head of the Department for cadaveric tissues preparation, Deputy Director, e-mail: miljudin@mail.ru
Volova L.T. ― D. Sc. (medicine), Professor of the Department of Operative Surgery and Clinical Anatomy, Director, tel. (846) 926-21-46, e-mail: leyla_tsurova@mail.ru
The article presents the issues of cosmetic and medico-social rehabilitation of patients after enucleation. The choice of implant material that meets all the requirements for orbital implants, and corresponds to the size and shape of the orbital cavity creates conditions for an individual approach to each patient, helps to avoid complications and provides social and cosmetic rehabilitation of anophthalmic patients. The literature review describes the properties of a biocompatible allogeneic orbital implant manufactured using an improved technique and used in ophthalmic surgery to create a post-nucleation stump as the best alternative to a synthetic orbital insert.
Key words: bone allogenic implant, enucleation, evisceration, musculoskeletal postnucleation stump, anophthalmic syndrome
(For citation: Tsurova L.M., Milyudin E.S., Volova L.T. Biocompatible allogenic bone implant in ophthalmic surgery. Practical Medicine. 2018)
REFERENCES
- Astakhov Yu.S., Nikolaenko V.P. Rezul’taty enukleatsii s implantatsiey orbital’nogo vkladysha iz poristogo politetraftoretilena pri posttravmaticheskoy subatrofii glaznogo yabloka [Results of enucleation with implantation of the orbital liner from porous polytetrafluoroethylene in posttraumatic subatrophy of the eyeball]. Lechenie posttravmaticheskoy patologii: mat. nauch.-prakt. konf. Moscow, 2004. Pp. 20-22.
- Astakhov Yu.S., Nikolaenko V.P. Pervyy opyt ispol’zovaniya orbital’nykh implantatov iz otechestvennogo poristogo politetraftoretilena [The first experience of using orbital implants from domestic porous polytetrafluoroethylene]. Sovrem. napravleniya v diagnostike, lechenii i profilakt. zabolevaniy. Saint Petersburg, 2002. Pp. 168-169.
- Nikolaenko V.P. Modern materials for the production of orbital implants. Klin. oftal’mologiya, 2005, vol. 6, no. 1, pp. 9-12 (in Russ.).
- Ivolgina I.V. Features of the application of various implants in the formation of the locomotor stump after enucleation. Vestnik TGU, 2015, no. 20, pp. 577-579 (in Russ.).
- Krasil’nikova V.L. Mediko-sotsial’naya reabilitatsiya patsientov s anoftal’mom s pomoshch’yu kompozitsionnogo oftal’mologicheskogo implantata (kliniko-eksperimental’noe issledovanie): avtoref. dis. … d-ra nauk [Medico-social rehabilitation of patients with an anophthalmus with the help of a composite ophthalmologic implant (clinical and experimental study). Synopsis of dis. Dr med. sci]. Saint Petersburg, 2007. 41 p.
- Nikolaenko V.P. Modern materials for the production of orbital implants. Klinicheskaya oftal’mologiya, 2005, no. 1, pp. 9-12.
- Nikolaenko V.P. Ispol’zovanie politetraftoretilenovykh implantatov v oftal’mokhirurgii (kliniko-eksperimental’noe issledovanie): dis. … d-ra med. nauk [The use of polytetrafluoroethylene implants in ophthalmic surgery (clinical and experimental research). Dis. Dr med. sci]. Saint Petersburg, 2005. 314 p.
- Takhchidi Kh.P., Cheglakov P.Yu. Metodika formirovaniya oporno-dvigatel’noy kul’ti s posleduyushchey kosmeticheskoy korrektsiey okrashennoy myagkoy kontaktnoy linzoy [Technique of formation of the locomotor stump followed by cosmetic correction with a colored soft contact lens]. Evro-Aziatskaya konf. po oftal’mokhirurgii, 2-ya: materialy. Ekaterinburg, 2001. Pp. 273-374.
- Shlyakhov M.I., Takhchidi Kh.P. Sposob zadney evistsero-enukleatsii s sokhraneniem perednego otrezka fibroznoy kapsuly glaza [Method of posterior eviscero-enucleation with preservation of the anterior segment of the fibrous capsule of the eye]. Evro-Aziatskaya konf. po oftal’mokhirurgi, 2-ya: materialy. Ekaterinburg, 2001. Pp. 281-282.
- Filatova I.A. Anoftal’m. Patologiya i lechenie [Anophthalmus. Pathology and treatment]. Moscow, 2007. 213 p.
- Rubin P.A.D., Popham J.K., Shore J.W. A new enucleation implant: conical shape with superior sulcus support. Meeting of ESOPRS, 13-th: Abstracts. Rostock; Venue, 1995. Pp. 114-115.
- Zapuskalov I.V., Gorbunova E.A., Krivosheina O.I. Modern principles of prevention of anophthalmic syndrome: methods of forming a locomotor stump, types of orbital implants. Byulleten’ sibirskoy meditsiny, 2017, 16 (1), pp. 118-131 (in Russ.).
- Suter A.J., Molteno A.C., Bevin T.V. et. al. Long term follow up of bone derived hydroxyapatite orbital implants. Br. J. Ophtalmol, 2002, 86, pp. 1287-1292.
- Custer P.L., Trinkaus K.M. Porous implant exsposure: incidence, management and morbidity. Ophtalmol. Plast. and Surg, 2007, 14 (1), pp. 37-44.
- Astakhov Yu.S., Nikolaenko V.P., D’yakov V.E. Ispol’zovanie politetraftoretilenovykh implantatov v oftal’mokhirurgii [Use of polytetrafluoroethylene implants in ophthalmic surgery]. Moscow, 2007. P. 16.
- Goryachev Yu.E. et al. Prichiny reoperatsiy pri anoftal’micheskom sindrome i poisk putey ikh ustraneniya [The reasons for the reoperations in the anophthalmic syndrome and the search for ways to eliminate them]. Glaznoe protezirovanie i plasticheskaya khirurgiya v oblasti orbity. Sb. nauchn. trudov. Moscow, 1987. Pp. 59-60.
- Morel X., D` Hermies F., Renard G. Conjunctiva break over orbital implant after enucleation. Abstract book of 16-th Meeting of ESOPRS. Budapest, 1998. P. 53.
- Iliff N.T. Complications in Ophthalmic surgery. Hurchilllivingstone. New York, Edinburgh, London, Melbourne, 1983. 98 p.
- Kennedy R.E. Enucleation, evisceration and exenteraton. 1983. Hurchilllivingstone. New York, Edinburgh, London, Melbourne. Pp. 487-513.
- Lekishvili M.V., Panasyuk A.F. New bioplastics in reconstructive surgery. Vestnik RAMN, 2008, no. 9, pp. 33-36 (in Russ.).
- Takhchidi Kh.P., Cheglakov P.Yu. Metodika formirovaniya oporno-dvigatel’noy kul’ti s posleduyushchey kosmeticheskoy korrektsiey okrashennoy myagkoy kontaktnoy linzoy [Technique of formation of the locomotor stump followed by cosmetic correction with a colored soft contact lens]. Evro-Aziatskaya konf. po oftal’mokhirurgii, 2-ya: materialy. Ekaterinburg, 2001. Pp. 273-374.
- Shlyakhov M.I., Takhchidi Kh.P. Sposob zadney evistsero-enukleatsii s sokhraneniem perednego otrezka fibroznoy kapsuly glaza [Method of posterior eviscero-enucleation with preservation of the anterior segment of the fibrous capsule of the eye]. Evro-Aziatskaya konf. po oftal’mokhirurgi, 2-ya: materialy. Ekaterinburg, 2001. Pp. 281-282.
- Filatova I.A. Anoftal’m. Patologiya i lechenie [Anophthalmus. Pathology and treatment]. Moscow, 2007. 213 p.
- Korzh N.A., Radchenko V.A., Kladchenko L.A. Implantation materials and osteogenesis. The role of induction and conduction in osteogenesis. Ortoped., travmatol. i protez, 2003, no. 2, pp. 150-157 (in Russ.).
- Tsurova L.M., Milyudin E.S. Results of using the allogeneic orbital implant after removal of the eyeball. Prakticheskaya meditsina, 2017, 9 (6), pp. 243-246 (in Russ.).
- Tsurova L.M., Milyudin E.S. et al. Patent RF no. 159838 ot 28.01.16. “Orbital’nyy implantat” [The patent of the Russian Federation no. 159838 from 28.01.16 «Orbital implant»].